16947

Parameters:

Definitions:


Reactions:

Remedy:

Program Continuation:


Channel %1 start via PLC is not allowed

%1 = Channel ID

This alarm is active with "Group Serupro" only. _Group Serupro" is activated by means of "$MC_SERUPRO_MODE BIT2" and enables the retrace support of entire channel groups during block search.

The machine data $MC_DISABLE_PLC_START specifies which channel is generally started from the PLC and which channel is only allowed to be started from another channel via the START part program command.

This alarm occurs if the channel was started via the PLC and $MC_DISABLE_PLC_START==TRUE was set.

- Alarm display.

Modify $MC_DISABLE_PLC_START of switch off "Group Serupro" (see $MC_SERUPRO_MODE).

Clear alarm with the Delete key or NC START.


1-871


© Siemens AG 2005 All Rights Reserved