Reactions:
Remedy:
Program Continuation:
Channel %1 interrupt treatment: action %2<ALNX> not possible
%1 = Channel number
%2 = Action number/action name
A program interrupt has been activated in a non REORG capable block. Examples of possible program interrupt in this case:
Traversing to fixed stop
VDI channel delete distance-to-go
VDI axial delete distance-to-go
Measuring
Software limit
Axis replacement
Axis from correction
Servo disable
Gear stage change at actual gear stage unequal to setpoint gear stage. The relevant block concerns a:
Pick-up block during block search (excluding last pick-up block)
Block in overstore interrupt.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Do not trigger the event on this block.
Clear alarm with the RESET key. Restart part program
© Siemens AG 2005 All Rights Reserved