16777

Channel %1 block %2 coupling: following axis %3 for lead axis %4 not available

Parameters:

%1 = Channel number

%2 = Block number, label

Definitions:

%3 = Axis name, spindle number %4 = Axis name, spindle number

A coupling has been switched on in which the slave spindle/axis is currently not available. Possible causes:

Reactions:

The spindle/axis is active in the other channel.

The spindle/axis has been accessed by the PLC and has not yet been released.

- NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Put the master spindle/axis with spindle/axis exchange into the necessary channel or release from the PLC.

Program Continuation:

Clear alarm with the RESET key. Restart part program

© Siemens AG 2005 All Rights Reserved

1-804