16777 |
Channel %1 block %2 coupling: following axis %3 for lead axis %4 not available |
Parameters: |
%1 = Channel number %2 = Block number, label |
Definitions: |
%3 = Axis name, spindle number %4 = Axis name, spindle number A coupling has been switched on in which the slave spindle/axis is currently not available. Possible causes: |
Reactions: |
The spindle/axis is active in the other channel. The spindle/axis has been accessed by the PLC and has not yet been released. - NC Start disable in this channel. |
Remedy: |
- Interface signals are set. - Alarm display. - NC Stop on alarm. Please inform the authorized personnel/service department. Put the master spindle/axis with spindle/axis exchange into the necessary channel or release from the PLC. |
Program Continuation: |
Clear alarm with the RESET key. Restart part program |
© Siemens AG 2005 All Rights Reserved