16751

Channel %1 block %2 spindle/axis %3 SPCOF not executable

Parameters:

%1 = Channel number

%2 = Block number, label

Definitions:

%3 = Axis name, spindle number

For the programmed function, the spindle must be in the open-loop control mode. In the positioning or axis mode, the position control must not be deselected.

Reactions:

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Remedy:

Put the spindle into open-loop control mode in the preceding block. This can be done with M3, M4 or M5 for the relevant spindle.

Program Continuation:

Clear alarm with NC START or RESET key and continue the program.

© Siemens AG 2005 All Rights Reserved

1-790