16751 |
Channel %1 block %2 spindle/axis %3 SPCOF not executable |
Parameters: |
%1 = Channel number %2 = Block number, label |
Definitions: |
%3 = Axis name, spindle number For the programmed function, the spindle must be in the open-loop control mode. In the positioning or axis mode, the position control must not be deselected. |
Reactions: |
- Correction block is reorganized. - Interface signals are set. - Alarm display. |
Remedy: |
Put the spindle into open-loop control mode in the preceding block. This can be done with M3, M4 or M5 for the relevant spindle. |
Program Continuation: |
Clear alarm with NC START or RESET key and continue the program. |