16730

Parameters:


Definitions:


Reactions:


Remedy:

Program Continuation:


Channel %1 block %2 axis %3 wrong parameter

%1 = Channel number

%2 = Block number, label

%3 = Axis name, spindle number

In G33 (tapping with constant lead) the lead parameter was not assigned to the axis that determines the velocity.

For longitudinal and face threads, the thread lead for the specified geometry axis must be programmed under the associated interpolation parameter.

X -> I Y -> J Z -> K

For taper threads, the address I, J, K depends on the axis with the longer path (thread length). A 2nd lead for the other axis is, however, not specified.

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Assign lead parameters to the axis that determines the velocity.

Clear alarm with NC START or RESET key and continue the program.


1-787


© Siemens AG 2005 All Rights Reserved