16423 |
Channel %1 block %2 angle %3 programmed repeatedly in the block |
Parameters: |
%1 = Channel number %2 = Block number, label |
Definitions: |
%3 = Angle It is not allowed to program more than one polynomial for the orientation rotation angle with PO[THT] in one block. |
Reactions: |
- Correction block is reorganized. - Interface signals are set. - Alarm display. |
Remedy: Program Continuation: |
Modify part program. Clear alarm with NC START or RESET key and continue the program. |
© Siemens AG 2005 All Rights Reserved