16300 |
Channel %1 block %2 denominator polynominal with zero places within parameter range not allowed |
Parameters: |
%1 = Channel number %2 = Block number, label |
Definitions: |
The programmed denominator polynomial (with PL [ ] = ... , i.e. without specification of geometry axis) has a zero place within the defined parameter range (PL = ...). This means that the quotient of the numerator polynomial and the denominator polynomial is infinite or indeterminate. |
Reactions: |
- Correction block is reorganized. - Interface signals are set. - Alarm display. |
Remedy: |
Modify the polynomial block so that there is no zero place within the polynomial length in the denominator polynomial. |
Program Continuation: |
Clear alarm with NC START or RESET key and continue the program. |
© Siemens AG 2005 All Rights Reserved