16300

Channel %1 block %2 denominator polynominal with zero places within parameter range not allowed

Parameters:

%1 = Channel number

%2 = Block number, label

Definitions:

The programmed denominator polynomial (with PL [ ] = ... , i.e. without specification of geometry axis) has a zero place within the defined parameter range (PL = ...). This means that the quotient of the numerator polynomial and the denominator polynomial is infinite or indeterminate.

Reactions:

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Remedy:

Modify the polynomial block so that there is no zero place within the polynomial length in the denominator polynomial.

Program Continuation:

Clear alarm with NC START or RESET key and continue the program.

© Siemens AG 2005 All Rights Reserved

1-770