16100

Channel %1 block %2 spindle %3 not available in the channel

Parameters:

%1 = Channel number

%2 = Block number, label

Definitions:

%3 = String

Mistake in programming: This channel does not recognize the spindle number. The alarm can occur together with a dwell or SPI function.

Reactions:

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Remedy:

Please inform the authorized personnel/service department. Check the part program to determine whether the programmed spindle number is correct and whether the program is run in the correct channel.

Check MD 35000 SPIND_ASSIGN_TO MACHAX for all machine axes to see whether one of them contains the programmed spindle number. This machine axis number must be entered in a channel axis of the channel-specific machine data 20070 AXCONF_MACHAX_USED.

Program Continuation:

Clear alarm with NC START or RESET key and continue the program.

© Siemens AG 2005 All Rights Reserved

1-760