Remedy:
Program Continuation:
Channel %1 block %2 touch probe not allowed
%1 = Channel number
%2 = Block number, label
Measure with deletion of distance-to-go
In the part program, an illegal probe has been programmed with the command MEAS (measure with deletion of distance-to-go). The probe numbers
0 ... no probe
1 ... probe 1
2 ... probe 2
are allowed, whether the probe is actually connected or not.
Example:
N10 MEAS=2 G01 X100 Y200 Z300 F1000 Probe 2 with deletion of distance-to-go
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Include a probe number within the limits given above in the keyword MEAS=... This must correspond to the hardware connection of the probe.
Clear alarm with NC START or RESET key and continue the program.