15700

Channel %1 block %2 illegal cycle alarm number %3

Parameters:

%1 = Channel number

%2 = Block number, label

Definitions:

%3 = Cycle alarm number

A SETAL command has been programmed with a cycle alarm number less than 60 000 or greater than 67 999.

Alarm reactions of Siemens standard cycles:

Nos. 61,000 -61,999: Interpreter stop; delete with Reset

Nos. 62 000 - 62 999: Compensation block; delete with NC Start

Reactions:

-    Interpreter stop

-    NC Start disable in this channel.

Remedy:

Program Continuation:

-    Interface signals are set.

-    Alarm display.

Program alarm number in the SETAL instruction in the correct range.

Clear alarm with the RESET key. Restart part program

© Siemens AG 2005 All Rights Reserved

1-746