Reactions:
Remedy:
Program Continuation:
Channel %1 block %2 instruction in current mode not allowed
%1 = Channel number
%2 = Block number, label
The alarm is output in the following situation:
The interpreter has detected an illegal instruction (e.g. a motion command) while processing an INI file or a definition file (macro or GUD).
In a GUD file, the access security for a machine data is to be changed with REDEF, although
an ACCESS file (_N_SACCESS_DEF, _N_MACCESS_DEF, _N_UACCESS_DEF) is available.
Access rights for machine data can only be changed then via one of the ACCESS files with REDEF.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Correct the INI, GUD or macro file.
Correct part program.
Clear alarm with the RESET key. Restart part program
© Siemens AG 2005 All Rights Reserved