15300
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
Channel %1 block %2 invalid number-of-passed-blocks during block search
%1 = Channel number %2 = Block number, label
In the function "Block search with calculation" a negative number of passes has been entered in column P (number of passes). The permissible range of values is P 1 - P 9 999. - Alarm display.
Enter only positive number of passes within the range of values.
Clear alarm with the Delete key or NC START.
1-729
© Siemens AG 2005 All Rights Reserved