15165 |
Channel %1 block %2 error when translating or interpreting Asup %3 |
Parameters: |
%1 = Channel number %2 = Block number, label |
Definitions: |
%3 = String At part program start and at start of an ASUB under Reset condition, the relevant data of all the ASUBs that can be activated at that time are preprocessed: PLC ASUBs |
Reactions: |
With $MC_PROG_EVENT_MASK configured event-controlled program calls ASUB after block search ($MN_SEARCH_RUN_MODE bit 1=1) Editable system ASUB ($MN_ASUP_EDITABLE) If an error occurs (converter or interpreter), alarm 15165 will be output first and then a converter or interpreter alarm that describes more details of the error. Alarm 15165 will cause an interpreter stop. A compensation block will not be possible. - Interpreter stop - NC Start disable in this channel. |
Remedy: Program Continuation: |
- Interface signals are set. - Alarm display. Modify part program. Clear alarm with the RESET key. Restart part program |
© Siemens AG 2005 All Rights Reserved