15165

Channel %1 block %2 error when translating or interpreting Asup %3

Parameters:

%1 = Channel number

%2 = Block number, label

Definitions:

%3 = String

At part program start and at start of an ASUB under Reset condition, the relevant data of all the ASUBs that can be activated at that time are preprocessed:

PLC ASUBs

Reactions:

With $MC_PROG_EVENT_MASK configured event-controlled program calls

ASUB after block search ($MN_SEARCH_RUN_MODE bit 1=1)

Editable system ASUB ($MN_ASUP_EDITABLE)

If an error occurs (converter or interpreter), alarm 15165 will be output first and then a converter or interpreter alarm that describes more details of the error. Alarm 15165 will cause an interpreter stop. A compensation block will not be possible.

-    Interpreter stop

-    NC Start disable in this channel.

Remedy:

Program Continuation:

-    Interface signals are set.

-    Alarm display.

Modify part program.

Clear alarm with the RESET key. Restart part program

© Siemens AG 2005 All Rights Reserved

1-716