15010 |
Channel %1 block %2 program coordination instruction with invalid channel number |
Parameters: |
%1 = Channel number %2 = Block number, label |
Definitions: |
A WAITM, WAITMC,INIT or START instruction was programmed with an invalid channel number. |
Reactions: |
- Correction block is reorganized. - Interface signals are set. - Alarm display. |
Remedy: Program Continuation: |
Correct the instruction accordingly. Clear alarm with NC START or RESET key and continue the program. |
© Siemens AG 2005 All Rights Reserved