14753 |
Channel %1 block %2 motion synchronous actions with illegal interpolation type |
|
Parameters: |
%1 = Channel number %2 = Block number, label |
|
Definitions: |
The active interpolation type (e.g. 5-axis interpolation) is not allowed for the motion synchronous action or for the function "Several feeds". |
|
Reactions: |
- Correction block is reorganized. - Interface signals are set. - Alarm display. |
|
Remedy: Program Continuation: |
Modify part program. Clear alarm with NC START or RESET key and continue the program. |