14751


Parameters:


Definitions:


Reactions:


Remedy:

Program Continuation:


Channel %1 block %2 resources for motion synchronous actions not sufficient (code: %3)

%1 = Channel number %2 = Block number, label %3 = Identifier

To process motion synchronous actions resources are required. They are configured via the machine data $MC_MM_IPO_BUFFER_SIZE, $MC_MM_NUM_BLOCKS_IN_PREP and $MC_MM_NUM_SYNC_ELEMENTS. If these resources are insufficient for executing the part program, then this alarm is issued. The parameter %3 shows which resource has run out:

Increase identifier <= 2: $MC_MM_IPO_BUFFER_SIZE or $MC_MM_NUM_BLOCKS_IN_PREP.

Increase identifier > 2: $MC_MM_NUM_SYNC_ELEMENTS.

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Correct part program or increase resources.

Clear alarm with NC START or RESET key and continue the program.


© Siemens AG 2005 All Rights Reserved


1-668