Channel %1 block %2 timeout during command to interpreter |
Parameters: |
%1 = Channel number %2 = Block number, label |
Definitions: |
A timeout has occurred in control-internal commands such as ANWAHL (part program selection), RESET (channel reset), REORG (reorganization of the preprocessing buffer) and NEWCONFIG (change in the configuration-specific machine data = warm restart). |
Reactions: |
- Interpreter stop - NC Start disable in this channel. |
Remedy: |
- Interface signals are set. - Alarm display. Please inform the authorized personnel/service department. If the runtime error occurred as the result of a temporary excessive load on the system (e.g. in the MMC area or in OEM application) error-free execution is possible on repeating the program or operator action. Otherwise, the A&D MC system support should be contacted with a precise description of the error situation: (contact SIEMENS AG, System Support for A&D MC products, Hotline (Tel.:see alarm 1000) |
Program Continuation: |
Switch control OFF - ON. |