14700

Channel %1 block %2 timeout during command to interpreter

Parameters:

%1 = Channel number

%2 = Block number, label

Definitions:

A timeout has occurred in control-internal commands such as ANWAHL (part program selection), RESET (channel reset), REORG (reorganization of the preprocessing buffer) and NEWCONFIG (change in the configuration-specific machine data = warm restart).

Reactions:

-    Interpreter stop

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

Please inform the authorized personnel/service department. If the runtime error occurred as the result of a temporary excessive load on the system (e.g. in the MMC area or in OEM application) error-free execution is possible on repeating the program or operator action. Otherwise, the A&D MC system support should be contacted with a precise description of the error situation:

(contact SIEMENS AG, System Support for A&D MC products, Hotline (Tel.:see alarm 1000)

Program Continuation:

Switch control OFF - ON.

© Siemens AG 2005 All Rights Reserved

1-658