14290 |
Channel %1 block %2 polynominal degree greater than 5 programmed for polynominal interpolation |
Parameters: |
%1 = Channel number %2 = Block number, label |
Definitions: |
A polynominal degree greater than five was programmed for the polynominal interpolation. You can only program polynomials up to the 5th degree. |
Reactions: |
- Correction block is reorganized. - Interface signals are set. - Alarm display. |
Remedy: Program Continuation: |
Modify part program. Clear alarm with NC START or RESET key and continue the program. |
© Siemens AG 2005 All Rights Reserved
1-616