14210

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Channel %1 block %2 polar angle too large

%1 = Channel number %2 = Block number, label

In specifying the endpoints in a traversing block with G00, G01, G02 or G03 in polar coordinates, the value range of the polar angle programmed under the keyword AP=... has been exceeded. It covers the range from -360 to +360 degrees with a resolution of 0.001 degrees.

Definition of terms:

Specification of end of block point with polar angle and polar radius, referring to the current pole (preparatory functions: G00/G01/G02/G03).

New definition of the pole with polar angle and pole radius, referring to the reference point selected with the G function. G110 ... referred to the last programmed point in the plane, G111 ... referred to the zero point of the current workpiece coordinate system (WCS), G112 ... referred to the last pole.

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Correct NC part program. The permissible input range for the polar angle is between the values -360 degrees and +360 degrees with a resolution of 0.001 degrees.

Clear alarm with NC START or RESET key and continue the program.


1-611


© Siemens AG 2005 All Rights Reserved