Reactions:
Remedy:
Program Continuation:
Channel %1 block %2 invalid base frame definition for tool carrier offset
%1 = Channel number %2 = Block number, label
If a tool carrier selection causes a change in the table offset, a valid base frame must be defined in order to store this offset; for more information see machine data 20184 (TOCARR_BASE_FRAME_NUMBER).
- Correction block is reorganized.
- Interpreter stop
- Interface signals are set.
- Alarm display.
Change the NC program or machine data 20184 (TOCARR_BASE_FRAME_NUMBER). Clear alarm with NC START or RESET key and continue the program.
© Siemens AG 2005 All Rights Reserved