14154


Parameters:


Definitions:


Reactions:


Remedy:

Program Continuation:


Channel %1 block %2 The amount of fine correction in parameter %3of the orientable toolholder %4 is too large

%1 = Channel number %2 = Block number, label

%3 = Invalid parameter of the orientable toolholder %4 = Number of the orientable toolholder

The maximum permissible value of the fine correction in an orientable toolholder is limited by the machine data $MC_TOCARR_FINE_LIM_LIN for linear variables, and by the machine data $MC_TOCARR_FINE_LIM_ROT for rotary variables. The alarm can only occur if the setting data $SC_TOCARR_FINE_CORRECTION is not equal to zero.

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm at block end.

Enter a valid fine correction value.

Clear alarm with NC START or RESET key and continue the program.


© Siemens AG 2005 All Rights Reserved


1-594