14116 |
Channel %1 block %2 absolute orientation programmed while ORIPATH/ORIPATHS is active |
Parameters: |
%1 = Channel number %2 = Block number, label |
Definitions: |
The orientation has been entered as an absolute value (e.g. by a direction vector or a rotation vector), although ORIPATH or ORIPATHS are active. When ORIPATH/ ORIPATHS is active, the orientation is determined from the lead angle, tilt angle and angle of rotation relative to the path tangent and surface normal vector. |
Reactions: |
- Correction block is reorganized. - Interface signals are set. - Alarm display. |
Remedy: Program Continuation: |
Modify part program. Clear alarm with NC START or RESET key and continue the program. |