14116

Channel %1 block %2 absolute orientation programmed while ORIPATH/ORIPATHS is active

Parameters:

%1 = Channel number

%2 = Block number, label

Definitions:

The orientation has been entered as an absolute value (e.g. by a direction vector or a rotation vector), although ORIPATH or ORIPATHS are active. When ORIPATH/ ORIPATHS is active, the orientation is determined from the lead angle, tilt angle and angle of rotation relative to the path tangent and surface normal vector.

Reactions:

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Remedy:

Program Continuation:

Modify part program.

Clear alarm with NC START or RESET key and continue the program.

© Siemens AG 2005 All Rights Reserved

1-562