14100

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

Channel %1 block %2 orientation transformation not available

%1 = Channel number %2 = Block number, label

Four transformation groupings (transformation types) can be set for each channel via machine data. If the keyword TRAORI(n) (n ... number of the transformation grouping) is used to address a transformation grouping for which the machine data is not defaulted, the alarm message will be triggered.

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction pointer positions on the incorrect block.

Check the number of the transformation grouping when calling the part program with the keyword TRAORI(n) (n ... number of the transformation grouping).

Enter the machine data for this transformation grouping and then activate by "Power On". Clear alarm with NC START or RESET key and continue the program.

1-553

© Siemens AG 2005 All Rights Reserved