14097

Parameters:

Definitions:

Reactions:

Remedy:


Program Continuation:


Channel %1 block %2 string cannot be converted to AXIS type

%1 = Channel number %2 = Block number, label

The called function AXNAME - conversion of the transferred parameters of the STRING type to an axis name (return value) of the AXIS type - has not found this axis identifier in the machine data.

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Please inform the authorized personnel/service department. Check the transferred parameters (axis name) of the function AXNAME to determine whether a geometry, channel or machine axis of this name has been configured by means of the machine data: 10 000: AXCONF_MACHAX_NAME_TAB 20 070: AXCONF_GEOAX_NAME_TAB 20 080: AXCONF_CHANAX_NAME_TAB

Select the transfer string in accordance with the axis name and change the axis name in the machine data if necessary. (If a change of name is to take place via the NC part program, this change must first be validated by means of a "Power On").

Clear alarm with NC START or RESET key and continue the program.


© Siemens AG 2005 All Rights Reserved


1-550