12710

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

Channel %1 block %2 illegal language element in external language mode

%1 = Channel number %2 = Block number, label

The programmed language element is not allowed or unknown in external language mode. Only the language elements from Siemens mode which are used for subprogram calls (except for Lxx) and the language constructs for program repetition with REPEAT (UNTIL) are allowed.

-    Correction block

-    Interface signals are set.

-    Alarm display.

Modify part program.

Check that the language command is available in Siemens mode. Switch to Siemens mode with G290. Program the command in the next block and switch back to the external language mode in the following block.

Clear alarm with NC START or RESET key and continue the program.

1-498