12590

Parameters:

Definitions:


Reactions:

Remedy:

Program Continuation:


Channel %1 block %2 global user data cannot be created

%1 = Channel number %2 = Block number, label

The number of global user data blocks is defined in machine data $MC_NUM_GUD_MODULES.

Here, _N_SGUD_DEF corresponds to block 1, _N_MGUD_DEF corresponds to block 2, _N_UGUD_DEF corresponds to block 3, _N_GUD4_DEF corresponds to block 4 etc.

In the directory _N_DEF_DIR there is a file with definitions for global user data, the block number of which is greater than the number of blocks given in the MD.

The alarm may, however, also be caused by value zero in one of MD $MN_MM_NUM_GUD_NAMES_NCK, $MN_MM_NUM_GUD_NAMES_CHAN and by the definition of a variable with NCK or CHAN in one of the GUD definition files.

-    Correction block

-    Interface signals are set.

-    Alarm display.

Please inform the authorized personnel/service department. Increase machine data 18118 MM_NUM_GUD_MODULES.

Or, if it already has the correct value, check whether 18120

$MN_MM_NUM_GUD_NAMES_NCK (if a variable has been defined with attribute NCK) or 18130 $MN_MM_NUM_GUD_NAMES_CHAN (if a variable has been defined with attribute CHAN) is not zero.

Clear alarm with NC START or RESET key and continue the program.


© Siemens AG 2005 All Rights Reserved


1-486