Channel %1 block %2 motion synchronous action: type conflict in variable %3

%1 = Channel number %2 = Block number %3 = Source symbol

Type conversion is not possible for on-line variables $A.. or $V.., which are evaluated or written in the interpolation cycle. Only variables of the same type can be used together in logic operations or assigned to one another.

Example 1:

WHENEVER $AA_IM[X] > $A_IN[1] DO ...

An on-line variable of the REAL type (actual value) cannot be compared with a variable of the BOOL type (digital input)

The operation is possible if the following change is made:

WHENEVER $AA_IM[X] > $A_INA[1] DO ...

Example 2:

WHENEVER ... DO $AC_MARKER[1]=$AA_IM[X]-$AA_MM[X]

Improvement:

WHENEVER ... DO $AC_PARAM[1]=$AA_IM[X]-$AA_MM[X]

-    Correction block

-    Interface signals are set.

-    Alarm display.

Modify part program: Use variables of the same type.

Clear alarm with the RESET key. Restart part program


© Siemens AG 2005 All Rights Reserved