Program Continuation:
Channel %1 block %2 tool/magazine OEM parameter not defined. Option not set. Option not set.
%1 = Channel number %2 = Block number, label
The programmed $TC_... Cx system variable is not known in the control.
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Correct the name used (writing error)
$TC_DPCx, $TC_TPCx, $TC_MOPCx, $TC_MAPCx, $TC_MPPCx, $TC_DPCSx, $TC_TPCSx, $TC_MOPCSx, $TC_MAPCSx, $TC_MPPCSx; with x=1,...10 These are the OEM parameters of the tools magazines, The corresponding machine data value is set to < 10, or the option 'TM OEM parameters' has not been set.
Use correct parameter number, or - if the name cannot be changed - set machine data correction (see $MN_MM_NUM_CC_TOA_PARAM, ... $MN_MM_NUM_CCS_TOA_PARAM, ...). )
Check the option (machine data are only effective when the option is enabled).
Clear alarm with NC START or RESET key and continue the program.