12552

Parameters:

Definitions:

Reactions:

Remedy:


Program Continuation:


Channel %1 block %2 tool/magazine OEM parameter not defined. Option not set. Option not set.

%1 = Channel number %2 = Block number, label

The programmed $TC_... Cx system variable is not known in the control.

-    Correction block is reorganized.

-    Interface signals are set.

-    Alarm display.

Correct the name used (writing error)

$TC_DPCx, $TC_TPCx, $TC_MOPCx, $TC_MAPCx, $TC_MPPCx, $TC_DPCSx, $TC_TPCSx, $TC_MOPCSx, $TC_MAPCSx, $TC_MPPCSx; with x=1,...10 These are the OEM parameters of the tools magazines, The corresponding machine data value is set to < 10, or the option 'TM OEM parameters' has not been set.

Use correct parameter number, or - if the name cannot be changed - set machine data correction (see $MN_MM_NUM_CC_TOA_PARAM, ... $MN_MM_NUM_CCS_TOA_PARAM, ...). )

Check the option (machine data are only effective when the option is enabled).

Clear alarm with NC START or RESET key and continue the program.


© Siemens AG 2005 All Rights Reserved


1-468