Channel %1 block %2 dimension of parameter %3 incorrect

%1 = Channel number %2 = Block number, label %3 = Source string

The following possibilities of error must be checked:

The current parameter is an array, but the formal parameter is a variable The current parameter is a variable, but the formal parameter is an array The current and formal parameters are arrays, but not with the dimensions to be defined.

-    Correction block

-    Interface signals are set.

-    Alarm display.

Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction pointer positions on the incorrect block. Correct the NC part program in accordance with the cause of error as listed above.

Clear alarm with NC START or RESET key and continue the program.