12320

Parameters:


Definitions:


Reactions:


Remedy:


Program Continuation:


Channel %1 block %2 parameter %3 is no variable

%1 = Channel number %2 = Block number, label %3 = Source string

A constant or the result of a mathematical expression has been assigned to a REF parameter instead of a variable at the time of the subroutine call, even though only variable identifiers are allowed.

Examples:

N10 XYZ (NAME_1, 10, OTTO) or N10 XYZ (NAME_1, 5 + AN NA, OTTO)

-    Correction block

-    Interface signals are set.

-    Alarm display.

Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction pointer positions on the incorrect block. Remove the constant or the mathematical expression from the NC block.

Clear alarm with NC START or RESET key and continue the program.


1-443