12250

Parameters:


Definitions:


Reactions:


Remedy:


Program Continuation:


Channel %1 block %2 nested macro %3 not possible

%1 = Channel number %2 = Block number, label %3 = Source string

The macro technique supplies a 1-line instruction or series of instructions with a new identifier by means of the keyword DEFINE. No further macro may be contained in the string of instructions (nesting). Example: N10 DEFINE MACRO1 AS G01 G91 X123 MACRO2 F100

-    Correction block

-    Interface signals are set.

-    Alarm display.

Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction pointer positions on the incorrect block.

Nested macros must be replaced by the full program information.

Clear alarm with NC START or RESET key and continue the program.


1-435


© Siemens AG 2005 All Rights Reserved