12160

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

Channel %1 block %2 range of values exceeded

%1 = Channel number %2 = Block number, label

The programmed constant or the variable exceeds the value range that has previously been established by the definition of data type.

-    Correction block

-    Interface signals are set.

-    Alarm display.

Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction pointer positions on the incorrect block.

Correct value of the constant or adapt data type. If the value for an integer constant is too great, it can be specified as real constant by adding a decimal point.

Example:

R1 = 9 876 543 210 Correct: R1 = 9 876 543 210.

Value range INTEGER: Value range REAL: 2-1022 to 2+1023 Clear alarm with NC START or RESET key and continue the program.

1-426