12150

Parameters:


Definitions:


Reactions:


Remedy:


Program Continuation:


Channel %1 block %2 operation %3 not compatible with data type

%1 = Channel number %2 = Block number, label %3 = String (violating operator)

The data types are not compatible with the required operation (within an arithmetic expression or in a value assignment).

Example 1:

Arithmetic operation N10 DEF INT OTTO N11 DEF STRING[17] ANNA N12 DEF INT MAX

N50 MAX = OTTO + ANNA Example 2:

Value assignment

N10 DEF AXIS DRILL N11 DEF INT OTTO : N50 OTTO = DRILL

-    Correction block

-    Interface signals are set.

-    Alarm display.

Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction pointer positions on the incorrect block. Alter the definition of the variables used such that the required operations can be executed.

Clear alarm with NC START or RESET key and continue the program.


1-425