12060

Parameters:

Definitions:


Reactions:

Remedy:

Program Continuation:


Channel %1 block %2 same G group programmed repeatedly

%1 = Channel number %2 = Block number, label

The G functions that can be used in the part program are divided into groups that are syntax defining or non-syntax defining. Only one G function may be programmed from each G group. The functions within a group are mutually preclusive.

The alarm refers only to the non-syntax defining G functions. If several G functions from these groups are called in one NC block, the last of these in a group is active in each case (the previous ones are ignored).

Syntax defining G functions: 1. to 4th G group Non-syntax defining G functions: 5. to nth G group

-    Correction block

-    Interface signals are set.

-    Alarm display.

Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction pointer positions on the incorrect block.

No remedy is required. You should, however, check whether the G function last programmed really is the one required.

Clear alarm with NC START or RESET key and continue the program.


© Siemens AG 2005 All Rights Reserved


1-416