12010

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

Channel %1 block %2 address %3 address type programmed too often

%1 = Channel number

%2 = Block number, label

%3 = Source string of the address

For each address type, it is defined internally how often it may occur in a DIN block (for instance, all axes together form one address type for which a block limit also applies).

-    Correction block

-    Interface signals are set.

-    Alarm display.

Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The correction pointer positions on the incorrect block.

The program information must be split up over several blocks (but make sure that the functions are of the non-modal type!).

Clear alarm with NC START or RESET key and continue the program.

1-411

© Siemens AG 2005 All Rights Reserved