10860

Channel %1 block %2 feedrate not programmed

Parameters:

%1 = Channel number

%2 = Block number, label

Definitions:

Reason:

Reactions:

In the displayed block, an interpolation type other than G00 (rapid traverse) is active. The

F value has not been programmed.

Path feed F is active, on change between linear and revolutional feedrate, F has not been programmed again.

The modal feed for corner/chamfer (FRCM) is active, on change between linear and revolutional feedrate FRCM has not been programmed again.

-    Correction block is reorganized.

-    Local alarm reaction.

Remedy:

-    Interface signals are set.

-    Alarm display.

Program feedrate in accordance with the interpolation type.

G93: The feedrate is specified as a time-reciprocal value under address F in [1/min].

G94 and G97: The feedrate is programmed under address F in [mm/min] or [m/min].

G95: The feedrate is programmed as revolutional feedrate under address F in [mm/ revolution].

G96: The feedrate is programmed as cutting rate under address S in [m/min]. It is derived from the current spindle speed.

Program Continuation:

Clear alarm with NC START or RESET key and continue the program.

© Siemens AG 2005 All Rights Reserved

1-370