10820
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
Channel %1 rotary axis/spindle %2 not defined
%1 = Channel number
%2 = Axis name, spindle number
Revolutional feed has been programmed for contouring and synchronous axes or for an axis/spindle. However, the rotary axis/spindle from which the feed is to be deduced is not available.
- Correction block is reorganized.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
Correct part program or set the setting data 43300 ASSIGN_FEED_PER_REV_SOURCE correctly.
Clear alarm with NC START or RESET key and continue the program.
1-369