10820

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

Channel %1 rotary axis/spindle %2 not defined

%1 = Channel number

%2 = Axis name, spindle number

Revolutional feed has been programmed for contouring and synchronous axes or for an axis/spindle. However, the rotary axis/spindle from which the feed is to be deduced is not available.

-    Correction block is reorganized.

-    Local alarm reaction.

-    Interface signals are set.

-    Alarm display.

Correct part program or set the setting data 43300 ASSIGN_FEED_PER_REV_SOURCE correctly.

Clear alarm with NC START or RESET key and continue the program.

1-369

© Siemens AG 2005 All Rights Reserved