10766

Parameters:


Definitions:


Reactions:


Remedy:

Program Continuation:


Channel %1 illegal change of surface orientation between block %2 and block %3

%1 = Channel number %2 = Block number, label %3 = Block number, label

This alarm occurs with 3D face milling when, at the time of block transition, the surface defined in the first block is continued in the second block with the rear side of the surface defined there. The block number in the alarm designates the second block.

-    Correction block is reorganized.

-    Local alarm reaction.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm at block end.

Modify part program.

Clear alarm with NC START or RESET key and continue the program.


1-341