10762

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

Channel %1 block %2 too many empty blocks between two traversing blocks with active tool radius compensation

%1 = Channel number %2 = Block number, label

The maximum permissible number of empty blocks is limited by a machine data.

-    Correction block is reorganized.

-    Local alarm reaction.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm at block end.

Modify part program

Modify machine data

Check whether SBL2 is activated. With SBL2, a block is generated from each part program line which can lead to exceeding the maximum permissible number of empty blocks between two traversing blocks.

Clear alarm with NC START or RESET key and continue the program.

1-337