Channel %1 channel-specific protection zone %2 reached with axis %3 during manual mode
%1 = Channel number %2 = Protection zone number %3 = Axis name
The workpiece-related channel-specific protection zone has been reached with the specified axis. Note that another tool-related protection zone is still active. The workpiece-related protection zone can be traversed when the PLC has issued an enable signal.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
Please inform the authorized personnel/service department. Protection zone can be traversed after enable signal from PLC.
Alarm display showing cause of alarm disappears. No further operator action necessary.