10654

Parameters:

Definitions:


Reactions:

Remedy:

Program Continuation:


Channel %1 waiting for synchronization start of gantry group %2

%1 = Channel number %2 = Gantry unit

Alarm message appears when the axes are ready for synchronization. The gantry unit can now be synchronized. The actual value difference between master and slave axis is greater than the gantry warning threshold MD 37110 GANTRY_POS_TOL_WARNING. The synchronization must be started again explicitly with the start gantry synchronization interface signal (DB31-48, DBX 29.4).

- Alarm display.

Please inform the authorized personnel/service department. See Description of Functions (Special Functions), G1 Gantry Axis

Alarm display showing cause of alarm disappears. No further operator action necessary.


1-299


© Siemens AG 2005 All Rights Reserved