10651

Parameters:

Definitions:


Reactions:


Remedy:


Program Continuation:


Channel %1 gantry configuration error. Error code %2

%1 = Channel number %2 = Reason

The gantry configuration set in the machine data is erroneous. Gantry unit and reason for objection can be found in the transfer parameter.

The transfer parameter is made up as follows.

%2 = error designation + gantry unit (XX).

%2 = 10XX => no master axis declared %2 = 20XX => no slave axis declared

%2 = 30XX => different contents in MD 30550 slave axis and master axis

%2 = 40XX => different channel or NCU assignment of the gantry axes

%2 = 50XX => no slave axis declared in this channel

2% = 60XX => different channel assignment of the master axis

%2 = 10000 => error: slave axis is geometry axis

%2 = 11000 => error: competing positioning axis as slave axis

%2 = 12000 => error: compile cycle axis as slave axis

%2 = 13000 => error: gantry axis is spindle

%2 = 14000 => error: gantry axis is Hirth geared

e.g. error code 1001 = no master axis declared, gantry unit 1.

-    NC not ready.

-    Mode group not ready, also effective for single axes

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Correct the machine data:

MD 37100 GANTRY_AXIS_TYPE

0: No gantry axis

1: Master axis grouping 1

11: Slave axis grouping 1

2: Master axis grouping 2

12: Slave axis grouping 2

3: Master axis grouping 3

13: Slave axis grouping 3

Switch control OFF - ON.


© Siemens AG 2005 All Rights Reserved