8100

Parameters:

Definitions:


Reactions:

Remedy:

Program Continuation:


Channel %1 block %2: function not possible

%1 = Channel number

%2 = Block number, label

Impossible due to embargo regulations:

1.    Synchronous actions: Writing of feed, override and axial offsets ($AA_VC, $AC_VC, $AA_OVR, $AA_VC and $AA_OFF) from synchronous actions as well as Continuous Dressing can be programmed only once in a block.

2.    Extended measurement: 'Cyclic measurement' (MEAC) and 'Measurement from synchronous action' is not possible.

3.    Axis interpolation: The number of axes interpolating with one another must not exceed 4 (this also includes synchronous coupling of axes via synchronous actions "DO POS[X]=$A..." "DO FA[X]=$A...").

-    Interpreter stop

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Modify part program.

Clear alarm with the RESET key. Restart part program


© Siemens AG 2005 All Rights Reserved


1-244