6454 |
Channel %1 block %2 tool change not possible. No distance relation available. |
Parameters: |
%1 = Channel ID %2 = Block number, label |
Definitions: |
The desired tool change is not possible. Neither the spindle nor the buffer magazine location have a distance relation. |
Reactions: |
- Correction block is reorganized. - Interface signals are set. - Alarm display. |
Remedy: |
Check whether the magazine data ($TC_MDP2) have been defined correctly. Check whether the alarm-causing program command _ e.g. TCI _ has been programmed correctly. |
Program Continuation: |
Clear alarm with NC START or RESET key and continue the program. |
© Siemens AG 2005 All Rights Reserved