6010

Parameters:

Definitions:

Channel %1 data block %2 not or not completely created, error code %3

%1 = Channel number %2 = String (block name)

%3 = Internal error code

Data management has detected an error in power-up. The specified data block may not have been created. The error number specifies the type of error. If the error number >100000, then there is a fatal system error. Otherwise, the user memory area was made too small. In this case the (user) error codes have the following meaning:

Error number 1: No memory space available

Error number 2: Maximum possible number of symbols exceeded

Error number 3: Index 1 outside of valid value range

Error number 4: Name in channel already exists

Error number 5: Name in NCK already exists

If the alarm occurs after cycle programs, macro definitions or definitions for global user data (GUD) have been introduced, the machine data for the NC user memory configuration have been incorrectly configured. In all other cases, changes to machine data that are already correct lead to errors in the user memory configuration.

The following block names (2nd parameter) are known in the NCK (all system and user data blocks; in general, only problems in the user data blocks can be remedied by user intervention:

_N_NC_OPT - System internal: option data, NCK global _N_NC_SEA - System internal: setting data, NCK global _N_NC_TEA - System internal: machine data, NCK global _N_NC_CEC - System internal: 'cross error compensation'

_N_NC_PRO - System internal: protection zones, NCK global _N_NC_GD1 - User: 1. GUD block defined by _N_SGUD_DEF, NCK global _N_NC_GD2 - User: 2. GUD block defined by _N_MGUD_DEF, NCK global _N_NC_GD3 - User: 3. GUD block defined by _N_UGUD_DEF, NCK global _N_NC_GD4 - User: 4. GUD block defined by _N_GUD4_DEF, NCK global _N_NC_GD5 - User: 5. GUD block defined by _N_GUD5_DEF, NCK global _N_NC_GD6 - User: 6. GUD block defined by _N_GUD6_DEF, NCK global _N_NC_GD7 - User: 7. 7th GUD block defined by _N_GUD7_DEF, NCK global _N_NC_GD8 - User: 8. GUD block defined by _N_GUD8_DEF, NCK global _N_NC_GD9 - User: 9. GUD block defined by _N_GUD9_DEF, NCK global _N_NC_MAC - User: Macro definitions _N_NC_FUN - User: Cycle programs

_N_CHc_OPT - System internal: option data, channel-specific _N_CHc_SEA - System internal: setting data, channel-specific _N_CHc_TEA - System internal: machine data, channel-specific _N_CHc_PRO - System internal: protection zones, channel-specific _N_CHc_UFR - System internal: frames, channel-specific _N_CHc_RPA - System internal: arithmetic parameter, channel-specific _N_CHc_GD1 - User: 1. GUD block defined by _N_SGUD_DEF, channel-specific _N_CHc_GD2 - User: 2. GUD block defined by _N_MGUD_DEF, channel-specific _N_CHc_GD3 - User: 3. GUD block defined by _N_UGUD_DEF, channel-specific _N_CHc_GD4 - User: 4. GUD block defined by _N_GUD4_DEF, channel-specific _N_CHc_GD5 - User: 5. GUD block defined by _N_GUD5_DEF, channel-specific _N_CHc_GD6 - User: 6. GUD block defined by _N_GUD6_DEF, channel-specific _N_CHc_GD7 - User: 7. 7th GUD block defined by _N_GUD7_DEF, channel-specific _N_CHc_GD8 - User: 8. GUD block defined by _N_GUD8_DEF, channel-specific _N_CHc_GD9 - User: 9. GUD block defined by _N_GUD9_DEF, channel-specific

1-146