4350

Parameters:

Definitions:

Reactions:

Remedy:

Program Continuation:

1-139

Channel %1 axis identifier %2 machine data %3 not consistent with machine data %4

%1 = Channel number %2 = String: Axis identifier %3 = String: MD identifier %4 = String: MD identifier

MD 32410 JOG_AND_POS_JERK_ENABLE (jerk limitation) and MD 35240 ACCEL_TYPE_DRIVE (acceleration reduction) have been defined as the initial setting for an axis. However, the two functions cannot be activated at the same time for one axis.

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Resetting of 32410 JOG_AND_POS_JERK_ENABLE or 35240 ACCEL_TYPE_DRIVE.

Switch control OFF - ON.