4350
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-139
Channel %1 axis identifier %2 machine data %3 not consistent with machine data %4
%1 = Channel number %2 = String: Axis identifier %3 = String: MD identifier %4 = String: MD identifier
MD 32410 JOG_AND_POS_JERK_ENABLE (jerk limitation) and MD 35240 ACCEL_TYPE_DRIVE (acceleration reduction) have been defined as the initial setting for an axis. However, the two functions cannot be activated at the same time for one axis.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department. Resetting of 32410 JOG_AND_POS_JERK_ENABLE or 35240 ACCEL_TYPE_DRIVE.
Switch control OFF - ON.
© Siemens AG 2005 All Rights Reserved