4347 |
Channel %1 invalid channel axis assignment in machine data %2[%3] |
Parameters: |
%1 = Channel number %2 = Name of machine data %3 = Transformation number |
Definitions: |
Machine data TRAFO_AXIS_IN_X contains an invalid entry. The following causes for the error are possible: The entry references a channel axis which does not exist. The entry is zero (no axis) but the transformation needs the relevant axis as a channel axis. |
Reactions: |
- Correction block is reorganized. - Interface signals are set. - Alarm display. - NC Stop on alarm at block end. |
Remedy: Program Continuation: |
Correct the entry in TRAFO_AXES_IN_X. Clear alarm with the RESET key. Restart part program |
© Siemens AG 2005 All Rights Reserved