4270

Parameters:

Definitions:

Reactions:

Remedy:


Program Continuation:


Machine data %1 assigns not activated NCK input/output byte %2

%1 = String: MD identifier %2 = Index

The specified machine data assigns a digital input/output byte or an analog input/output signal the processing of which has not been activated to an NC function.

-    NC not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Correct machine data. Activate required inputs/outputs via MDs:

$MN_FASTIO_DIG_NUM_INPUTS

$MN_FASTIO_DIG_NUM_OUTPUTS

$MN_FASTIO_ANA_NUM_INPUTS

$MN_FASTIO_ANA_NUM_OUTPUTS

Activation of fast inputs/outputs does not require the corresponding hardware configuration to be available at the control. All functions using fast inputs/outputs can also be made use of by the PLC specification/modification defined in the VDI interface, if the response time requirements are reduced accordingly.

Activated inputs/outputs increase the computation time requirement of the interpolation cycle because the PLC manipulation signals are handled cyclically. Note: Deactivate any inputs/outputs not in use.

Switch control OFF - ON.


1-119