4160

Channel %1 invalid M function number configured for spindle switchover

Parameters:

Definitions:

%1 = Channel number

An M function was specified in machine data $MC_SPIND_RIGID_TAPPING_M_NR in order to configure the M function number for spindle switchover. The M function number is assigned by the system and cannot be used for the switchover (M1 to M5, M17, M30,

M40 to M45).

Reactions:

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

(M1 to M5, M17, M30, M40 to M45). Configure an M function which is not used by the system (M1 to M5, M17, M30, M40 to M45) in machine data $MC_SPIND_RIGID_TAPPING_M_NR.

Program Continuation:

Switch control OFF - ON.

© Siemens AG 2005 All Rights Reserved

1-100