Illegal configuration of the 'Block display with absolute values' function
The "Block display with absolute values" function has been illegally parameterized:
An illegal block length has been set with $MC_MM_ABSBLOCK:
While ramping up, the machine data will be checked for the following value range: 0, 1, 128 to 512
An invalid display range has been set with $MC_MM_ABSBLOCK_BUFFER_CONF[]. While ramping up, the machine data will be checked for the following upper and lower limits:
0 <= $MC_MM_ABSBLOCK_BUFFER_CONF[0] <= 8
0 <= $MC_MM_ABSBLOCK_BUFFER_CONF[1] <= ($MC_MM_IPO_BUFFER_SIZE + $MC_MM_NUM_BLOCKS_IN_PREP). Alarm 4152 is issued if the limits are violated.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Configure block length/display range within the permissible limits.
Switch control OFF - ON.